Module Level Rapid Shutdown Device BFS-A1 Monitoring Version

Module Level Rapid Shutdown Device BFS-A1 Monitoring Version

The BFS-A1Monitor version is a module-level rapid shutdown device designed to enhance fire safety for solar rooftops and buildings. It maintains rapid shutdown functionality throughout the entire lifespan of the solar PV system. The accompanying RSD monitoring equipment is required to utilize monitoring functions. Additionally, the monitoring equipment is equipped with emergency stop functionality alongside its monitoring capabilities.
Send Inquiry
Description

Application

The BFS-A1 Monitoring version is a module-level rapid shutdown device designed to enhance fire safety for solar rooftops and buildings. It maintains rapid shutdown functionality throughout the entire lifespan of the solar PV system.

Utilizing a unique POWERBUS communication method, it continuously monitors the temperature, voltage, current, and other data of the Rapid Shutdown Device (RSD) in real-time. This enables immediate observation of RSD status and early detection of issues, facilitating replacement and maintenance, thereby enhancing the safety of the PV power generation system.

The accompanying RSD monitoring equipment is required to utilize monitoring functions. Additionally, the monitoring
equipment is equipped with emergency stop functionality alongside its monitoring capabilities.

 

Advantage

*Module Level Rapid Shutdown With Monitoring Fuction

*Aluminum Enclosure With Higher Safety

*Manual Shutdown by emergency button 

*Level and Better Heat Dissipation Functior

*Automatic Shutdown on AC Power Loss

*Over temperature Automatic Shutdown

*Compatible with most string invertersand panels

*No cross-talk with inverter or WIFI

 

How the solution works?

1111111

The diagram above illustrates a typical 2-to 1 configured BFS protected installation using four solar panels and two BFS-A1. One more thing on the rooftop is the connection of BFS-A1 and the button switch via a communication cable.

 

 

2222222

A complete RSD solution:

Automatic shut down the panels upon detecting the inside temperature exceeding 100℃.

Automatic shut down the panels in the button switch box in case of AC power supply loss.

The firefighter can manually use the button switch to shut down the panels in case of an emergency.

 

SPECIFICATION

  

DC Power Supply for each RSD

  

  Voltage Range 14V ~ 28V Maximum Current 15mA Maximum Power 0.2W Power Supply Cables (Signal Cables) 2*0.823mm² (18AWG) Signal Cable + Signal Connectors Power Supply Cables Length 1800mm Mechanical   Enclosure Material Aluminum Dimension 118mm*107mm*28.4mm

 