With the maximum output power of 820 VA, BENY BYM800 microinverter connect to 1 or 2 panel and enable module-level maintenance and management of the PV station by monitoring power generation of each module.
Module-level data can be uploaded to the monitoring platform via BENY data transfer units through PLCC/Wifi.
The products are fully designed, with real materials, the main control chips, power devices, magnetic components and resistance components are all selected from the top international manufacturers, MTBF> 25 years. The structure and heat dissipation design are fully designed to ensure that it can still work at full load when the ambient temperature is 55℃.

Compared with APsystems, Hoymiles, and Deye, BENY Micro-inverter has the most outstanding performance.
BENY Single-In Micro-inverter has the highest output power (rated, peak value), maximum continuous current and warranty years.
Compliance:
VDE-AR-N 4105, EN50549-1, NC RFG, C10/11, INMETRO ABNT ABR 16149/16150/62116, CEI-0-21, AS/NZS 4777, VFR2019, G98, IEC/EN61000, IEC/EN62109
- * Adapted to 60~75 cells/120~150 sub cells PV panels
- * Static MPPT efficiency 99.80%
- * Peak efficiency 96.5%
- * EURO efficiency 96%
- * High reliability, IP67 (NEMA 6) enclosure, 6000 V surge protection
SPECIFICATION
| Input Data(DC) | |||
| Model | BYM800 | ||
| Recommended lnput Power(Single) | (STC)600~700+Wp , 60~75 cells/120~150sub cells | ||
| Recommended lnput Power(Dual) | (STC)(350~600 Wp) * 2 , 72~75 cells/144~150 sub cells (NMOT) Vmp≥32V and lmp≤15A |
||
| MPPT voltage range | 24V-50V | ||
| Operating voltage range | 16V-60V | ||
| Maximum DC input voltage | 60V | ||
| Maximum short circuit input current | 30A * 1 / 20A * 2 | ||
| Maximum continuous input current | 26A * 1 / 13A * 2 | ||
| Output Data(AC) | |||
| Rated Output Power | 800W | ||
| Maximum Output Power | 820VA(Vac≥230,Vmp≥35) | ||
| Rated voltage/range | 220V/230V/240V/176-265V | ||
| Rated frequency/range | 50Hz/60Hz (46.5-62)Hz | ||
| Maximum continuous output current | 3.64A | ||
| Maximum harmonic distortion | <3% | ||
| Power Factor | >0.99 (Default) | ||
| Maximum connection number in one string |
6 units(24A circuit breaker, 10AWG cable) | ||
| Efficiency | |||
| Peak efficiency | 96.50% | ||
| MPPT Efficiency | >99.8% | ||
| Night Power Consumption | <100mW | ||
| Other parameters | |||
| Communication Method | PLCC/WIFI | ||
| Safety Protection | Class I | ||
| Enclosure Rating | IP67 | ||
| Operating Temperature | -40℃ to +70℃ | ||
| Storage Temperature | -40℃ to +85℃ | ||
| Relative Humidity | 0-98% | ||
| Transformer Design | High frequency transformer, Electrical isolated | ||
| Overvoltage Class | OVC III (AC), OVC II (PV) | ||
| Dimensions(L*W*H mm) | 218*215*40 | ||
| Weight(kg) | 2.69 | ||
| Warranty Period | 10 / 25years Optional | ||
| Safety Regulations | IEC/EN 61000-6, CISPR11+A1+A2, IEC/EN 62109-1/2, EN 50549-1:2019 VDE-AR-N 4105:2018/DIN VDE 0124:2020, AS 4777.2 :2020, INMETRO, UTE C15- 712-1/DIN VDE 0126/VFR 2019, G98, CEI 0-21:2020, NC RFG, NTS DAKKS |
||
Monitoring Device
Communication with BENY microinverters through PLCC/WIFI enables users to manage the
systems in a smart digital way.

Hot Tags: Dual-In Microinverter 800, China, suppliers, manufacturers, factory, customized, quotation